The Details Make the Difference in Wind Design

By James Willits 08-23-2017
QUICK SHARE
Tag Icon

Roofing design encompasses many different factors. The assembly is dictated by the use of the building, the owner's budget, the building's location, local building codes, energy codes, and the forces of nature that are regularly, as well as occasionally unleashed upon it. In addition, a change in one part of the building envelope can adversely affect something else. As this implies, there are often many choices that the designer has to make. It is important to note that the installer also has a great effect on the overall performance of the system. Communication between the designer and the installer is paramount to the success of the system. The designer needs to relay exactly what components should comprise the assembly, as well as how the system should be installed. Conversely, the installer should alert the designer of any conditions or potential changes that do not match the plans and specification, since a small change can affect the entire envelope.

Communication between the designer and the installer is paramount to the success of the system.

Let's talk about golf for a moment. A 300-yard drive has exactly the same value on the scorecard as a 6-inch putt. The same is true on the roof. If the installer omits sealant and a clamp on a pipe flashing detail because the incorrect one was displayed in the plans, it has the same result as a cold-welded seam: Water in the building. So nearly every detail, no matter how small, can have the same effect. One such mishap may be small, but like strokes on the scorecard, they all add up.

There are certain details that often get overlooked. Sometimes specifications and plans don't match. If that happens, which one prevails? Sometimes plans trump details, others the opposite is true. Very often, perhaps in the interest of conserving time or effort, a specification or plan detail will state to comply with an established standard, such as those published by FM (Factory Mutual, which does its own system testing for its member insurance companies), SMACNA (Sheet Metal and Air Conditioning Contractors National Association), or the International Plumbing Code without specifying which exact detail or practice. One very common mistake, for example, is specifying FM 1-105 on an OSB deck, but FM doesn't test over combustible decks. So according to FM, a system over an OSB deck wouldn't be rated to withstand 105 pounds per square foot, or PSF, of uplift pressure. Perhaps, in that case, it would be better to outline specific enhanced fastening patterns or fastener pull out values.

Sometimes specifications and plans don't match. If that happens, which one prevails?

The designer of record can possibly open themselves up to liability if they leave details up to the installer's interpretation. Quite often, trades will mix and match responsibility of interfacing details, such as components of drains, counterflashing roof edge termination, coping cap waterproofing, and HVAC transitions to name a few. Returning to the situation where FM 1-105 over an OSB deck has been specified, the designer should ideally have consulted with the membrane manufacturer to identify options that have been demonstrated to conform to established standards. Good and experienced suppliers do a lot of system testing to understand how to achieve required levels of performance with as many options as feasible.

Wind Uplift — The Basics

Wind Pressure

Wind uplift, in general, is the upward force pulling on the building components as a result of wind blowing around and over the building. The roof is naturally exposed to these forces due to its location. When the wind flow moves over the edge of the roof it creates negative pressure. In addition, positive pressure exerted from inside the building from HVAC and openings such as doors and windows can also contribute to these forces, depending upon the building's construction.

Edges are Critical

Roof Field

Corners and perimeter zones are especially vulnerable to wind uplift forces due to their proximity to the edge. Vortices are created at corners, which can increase the upward pull. The next illustration is a top view of the roof, identifying perimeter and corner zones. As a rule of thumb, attachment (uplift resistance) is enhanced at a rate of 1.5x at the perimeter and 2x in the corner to combat these forces. Roof edge termination is especially critical, since it is at the leading edge holding the roof to the structure.

This fully adhered TPO roof was peeled back from the edge during a wind event, separating insulation layers.

This fully adhered TPO roof was peeled back from the edge during a wind event, separating insulation layers.

Roof edge termination is instrumental in resilience to these forces. Remember the golf analogy? Well, nearly every detail counts the same on the scorecard. Imagine this: You are on the 8th tee just starting your backswing when a meteor the size of a 1966 Volkswagen Beetle crashes in the middle of the fairway leaving a huge smoking crater. This is not simply a stroke, but instead, it is a catastrophic ending to the game (and quite a story). The same is true with the roof edge. A few years ago, the National Roofing Contractors Association, NRCA, independently tested numerous roof edge terminations. Mark Graham, the Vice President of Technical Services for the NRCA stated in an article featured in Professional Roofing magazine, "...flexural failure during edge metal testing is much more common than fastener pull-out:" The act of just adding more fasteners will not suffice, because if the metal is an insufficient gauge for the application, it will flex, allowing wind to lift it. It is reasonable to assume that when the edge catches air, the rest of the system is likely to follow like dominoes.

Roof edge termination is especially critical, since it is at the leading edge holding the roof to the structure.

Attention to Detail

So, if edges are critical, what is to be done? Ideally two things are recommended; first, instead of a general reference to compliance with SMACNA standards, it would be prudent to call out the exact detail that should be applied in specific locations. Second, the specifier may want to designate which trade is the best to be responsible for each detail, as opposed to leaving the decision up to the trades to decide what to include or exclude within their respective scopes. If a SMACNA detail is to be applied, then perhaps a sheet metal contractor may be the better choice to be responsible for that scope.

Picture1

TP-3 Courtesy of NRCA Guidelines for Single-ply Membrane Roof Systems

Take a moment to look at one common example from the NRCA, which is generally understood to be considered "good roofing practice." Shown above is Detail TP-3 from the NRCA Guidelines for Single-ply Membrane Roof Systems.

The field membrane extends over the roof edge, and down the wood nailer, and is secured by the fastening of the anchoring cleat on the face. The thermoplastic (TPO or PVC) coated metal is then placed on top of the membrane and fastened based upon the Architectural Metal Flashing Securement options found within the NRCA Roofing manual. That detail is completed with a hot air welded flashing strip that ties the roof membrane to the Thermoplastic coated metal for a watertight assembly. That is a roofing detail to be installed by a roofer. Imagine for a moment that the owner wanted to save some money; would you, as the designer, decide to do it here? Keep in mind that even though the assembly may qualify for a standard warranty, the owner is still exposed to the inconvenience of dealing with replacement, as well as collateral damage such as lost wages due to clean up, lost merchandise due to damage, and lost use of space while waiting for repair. There are other ways for a designer to save money on the assembly that do not significantly increase the risk of the roof blowing off. Remember the meteor? The diagram on the right is from ANSI/SPRI/FM 4435/ ES-1-11.

Picture2

This document establishes standards for roof edge details as they relate to wind uplift resistance based upon actual testing from collaboration with ANSI (American National Standards Institute), SPRI (Single Ply Roofing Industry), and FM (Factory Mutual). It illustrates one of the methods of testing the edge termination. This demonstrates a mechanically attached system with the same detail as above (NRCA TP-3). A load is applied to the field membrane at a 25 degree angle from the deck to simulate the stresses of the field sheet billowing. How would the less expensive alternate detail fare in this test?

...even though the assembly may qualify for a standard warranty, the owner is still exposed to the inconvenience of dealing with replacement...

The table below is from ANSI/SPRI/FM 4435/ ES-1-11:

ANSI chart

Courtesy of ANSI/SPRI/FM 4435/ES-1-11

Pay special attention to a few things; first, it shows the recommended minimum gauge for each metal (a thicker gauge can be specified for added strength); second, it is based upon the width of the exposed metal, so the wider it is, the thicker it should be. ES-1-11 outlines design criteria for wind uplift for edge details. This document is created as a guide to keep roofs where they belong.

Wrapping it Up

The designer of record, whether an Architect or a Consultant, should be decisive, and choose specific appropriate details. The owner is looking for a roof that is resilient, cost-effective, and does not cause any problems. Keep ANSI/SPRI/FM 4435/ ES-1-11 close, and don't risk your reputation in the hands of the lowest bidder. Ask any golf pro and they will tell you that putting is 40% of your game, so you had better make it 40% of your practice.

ABOUT THE AUTHOR
James has over a decade of experience in the roofing industry as an installer, a project manager, a sales person, and a training manager. As the GAF CARE Training Operations Manager, he translates his industry knowledge and experience into the practical installation of roofing systems. James is well regarded for presenting training and seminars that cover roofing theories and practice to a range of audiences.
Don't miss another GAF RoofViews post!
LATEST UPDATES
Even the smallest details play a role in a roof's effectiveness and integrity. Shingles and flashing are among the most noticeable roofing materials, but roof nails often get overlooked—despite being just as important as more obvious elements. And since they can greatly differ in size, material, and length, using the wrong nails to secure certain areas can cause all kinds of problems down the road.
The best roof shingles not only help protect your family's most important investment but also provide attractive curb appeal that can increase your home's value. GAF's new line of architectural shingles, Timberline® UHDZ™, Ultra High DefinitionTM Shingles improve upon their high-quality legacy products by combining the latest technology with an added beauty that delivers extended benefits for homeowners.
Do you know the warning signs of poor ventilation in a house and attic? Proper ventilation is important in many ways and one of the first big things to know is that it can prolong the life of your roof system. It can also help lower your attic temperature and thereby reduce HVAC wear and tear, which may help lower utility bills and the likelihood of costly repairs. And last, but definitely not least, attic ventilation can help reduce the risk of mold, which can protect the health of your family. All-in-all, attic ventilation offers a long-term return on investment as well as potential preventative health benefits.
Michigan City has been home to a GAF manufacturing facility since 2000, supporting the community's residents through not only the nearly 200 jobs it provides but also countless hours of volunteering. The job creation and increased capacity for serving customers with the GAF Michigan City distribution center expansion is testimony to the company's dedication to building resilient communities.
Getting multiple professionals involved in a commercial roofing project offers a way to capture different perspectives—and to shine a light on some of the industry's hidden complexities—especially when it comes to challenging details like parapet walls.
Asphalt shingles are one of the most widely used roofing materials, providing an elegant yet effective look for homes while also being economical and easy to install. Here is what makes these shingles stand out from other roofing materials.
This blog contains information created by a variety of sources, including internal and third party writers. The opinions and views expressed do not necessarily represent those of GAF. The content is for informational purposes only. It is not intended to constitute financial, accounting, tax or legal advice. GAF does not guarantee the accuracy, reliability, and completeness of the information. In no event shall GAF be held responsible or liable for errors or omissions in the content or for the results, damages or losses caused by or in connection with the use of or reliance on the content.

Interested in sharing or republishing our content? We kindly ask you to adhere to our guidelines.