Submittals Made Simple

Simplify your submittal process with GAF
Prepare for your next construction project more efficiently using our new submittals made simple option - created specifically for professionals. Our packages contain the documents and specs you need for GAF’s most popular systems: a CSI–formatted Guide Specification, Product and Safety Data Sheets, a Sample Guarantee, and Details. Browse our systems below to download, email, or print all of your required materials in just a few clicks.

5 Simple Steps


1.    
Use our Selection Guide, Roof Advisor Tool, or browse this page to select your best package.

 

2.    Download and review the prepared documents.


3.    
Use as-is or edit as desired. Multiple product options appear in red throughout the spec and can be deleted if not appropriate.


4.    
Remove product data and safety data sheets for omitted products.


5.    
Submit the package by print or email as required.

EverGuard® TPO

60 Mil TPO, Insulated, New Construction or Tear Off


• Wood or Steel Deck
• 2 Layers of Insulation
      Layer 1 - ISO
      Layer 2 - ISO or HD ISO
• 20 yr NDL Guarantee
• Master or Master Select Contractor

60 Mil Fleece-Back TPO, Non-Insulated,
New Construction or Tear Off

• Concrete Deck
• 20 yr NDL Guarantee
• Master or Master Select Contractor

60 Mil TPO, Insulation, Recover

• Existing Substrate
• Insulation
      HD ISO
• 20 yr NDL Guarantee
• Master or Master Select Contractor

60 Mil TPO, Insulation, New Construction or Tear Off

• Wood or Steel Deck
• 2 Layers of Insulation
      Layer 1 - ISO
      Layer 2 - ISO
• 20 yr NDL Guarantee
• Master or Master Select Contractor

60 Mil Fleece-Back TPO, Non-Insulated, Recover

Existing Substrate
• 20 yr NDL Guarantee
• Master or Master Select Contractor

60 Mil TPO, Insulated, Recover

Existing Substrate
• Insulation
    ○ HD ISO

• 20 yr NDL Guarantee
• Master or Master Select Contractor

60 Mil TPO, Insulated, New Construction or Tear Off

•  Existing Substrate
•  Insulation
    ○  Layer 1 - ISO
    ○  Layer 2 - ISO or HD ISO

•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil TPO, Insulated, Metal Retrofit

•  Metal Retrofit
•  Insulation
    ○  Layer 1 - Flute Fill ISO
    ○  Layer 2 - ISO

•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil TPO, Insulated, Recover

•  Existing Substrate
•  Insulation
    ○  HD ISO

•  20 yr NDL Guarantee
•  Master or Master Select Contractor

EverGuard Extreme® TPO

60 Mil Extreme TPO, Insulated, New Construction or Tear Off

•  Wood or Steel Deck
•  2 Layers of Insulation
    ○  Layer 1 - ISO
    ○  Layer 2 - ISO or HD ISO

•  30 yr NDL Guarantee
•  Master Select Contractor

60 Mil Fleece-Back Extreme TPO, Non-Insulated, New Construction or Tear Off

 

•  Concrete Deck
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil Extreme TPO, Insulation, Recover

•  Existing Substrate
•  Insulation
    ○  HD ISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil Extreme TPO, Insulation, New Construction or Tear Off

•  Wood or Steel Deck
•  2 Layers of Insulation
    ○  Layer 1 - ISO
    ○  Layer 2 - ISO
•  25 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil Fleece-Back Extreme TPO, Non-insulated, Recover

•  Existing Substrate
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil Extreme TPO, Insulated, Recover

•  Existing Substrate
•  Insulation
    ○  HDISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil Extreme TPO, Insulated, New Construction or Tear Off

•  Wood or Steel Deck
•  Insulation
    ○  Layer 1 - ISO
    ○  Layer 2 - ISO or HD ISO
•  30 yr NDL Guarantee
•  Master Select Contractor

60 Mil Extreme TPO, Insulated, Metal Retrofit

•  Metal Retrofit
•  Insulation
    ○  Layer 1 - Flute Fill ISO
    ○  Layer 2 - ISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil Extreme TPO, Insulated, Recover

•  Existing Substrate
•  Insulation
    ○  HD ISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

Everguard® PVC

60 Mil PVC, Insulated, New Construction or Tear Off

•  Wood or Steel Deck
•  2 Layers of Insulation
    ○  Layer 1 - ISO
    ○  Layer 2 - ISO or HD ISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil fleece-back PVC, Non-Insulated,
New Construction or Tear Off

•  Concrete Deck
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil PVC, Insulated, Recover

•  Existing Substrate
•  Insulation
    ○  HD ISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil PVC, Insulation, New Construction or Tear Off

•  Wood or Steel Deck
•  2 Layers of Insulation
    ○  Layer 1 - ISO
    ○  Layer 2 - ISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor
 

60 Mil PVC, Non-Insulated, Recover

•  Existing Substrate 
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil PVC, Insulated, Recover

•  Existing Substrate
•  Insulation
    ○  HD ISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil PVC, Insulated, New Construction or Tear Off

•  Wood or Steel Deck
•  Insulation
    ○  Layer 1 - ISO
    ○  Layer 2 - ISO or HD ISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil PVC, Insulated, Metal Retrofit

•  Metal Retrofit
•  Insulation
    ○  Layer 1 - Flute Fill ISO
    ○  Layer 2 - ISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

60 Mil PVC, Insulated, Recover

•  Existing Substrate
•  Insulation
    ○  HD ISO
•  20 yr NDL Guarantee
•  Master or Master Select Contractor

Customized Submittal Packages
Don't see what you need in the prepared submittals packages above?  No problem.  GAF AIS prepares customized submittal packages with all the information you need to bid on your upcoming project.  Just complete the Specification & Submittal Request Form below, and we'll send electronic or hard-copy packages at no charge to you.

 

Low-Slope Submittal Form   Steep-Slope Submittal Form

We're Here to Help

GAF Architectural Information Services is here to help answer questions, provide assistance
with master specification preparation and other valuable activities at no charge.

Call us at 877-423-7663, option 4
Email us at AIS@gaf.com

 

LATEST FROM GAF ROOF VIEWS
When designing and specifying a low-slope roofing system, it's important to consider the roof system's ability to resist external fire. Now, there are products available that can provide the necessary fire rating for your roofing system while also helping your building achieve credits toward LEED certification.
The roofing system on a cold storage facility will be very different from that of a traditional building. Whether the building stores refrigerated foods, frozen foods, plants, flowers, life-saving medications, or something else entirely, the roofing system plays an important role in keeping cold air inside the building.
Introduction Wind design of roof systems can be confusing from an engineering perspective. Wind design can also be confusing because the International Building Code (IBC) provides specific requirements, but so does Factory Mutual (FM). If FM is specified, do the IBC requirements need to be followed? What is the wind-design strategy for FM-insured and non-FM-insured buildings? This blog will discuss the following:
Low slope roof penetrations can be a source of problems if not done correctly. Pipe, vent, and conduit penetrations through low slope roof assemblies can cause problems for an otherwise tight membrane, insulation, and deck design. With many intermediate layers in roof assemblies, such as a vapor retarder and cover board, there are opportunities for things not to be done correctly somewhere in the assembly. It gets even more complex when we consider that in order to use a vapor retarder, there might be an additional cementitious board above a steel deck.