Roofing systems must be designed and installed to address the many sources of moisture that can affect a building. Roofing manufacturers can provide the materials with a range of properties and options for the roofing system designer, but because each building is unique the final responsibility for ensuring that moisture and condensation don't cause problems lies with the architect, system designer, project engineer, and/or roofing system professional.

Several years ago, SPRI issued an advisory bulletin on moisture and its effect on roofing systems. Their classification of the types of situations leading to moisture build-up is a good way to think about the main scenarios. I've listed them here, along with some general roofing system guidelines that may be useful. Of course, these guidelines should be superseded by those of a professional roof system designer.

1. Buildings with Small Amounts of Occupancy-Generated Moisture

These are the most common situations, covering office, retail, and warehouse spaces, for example. Warm air migrates upward and carries moisture with it. In northern climates, regardless of the membrane type, condensation can occur between the membrane and the insulation. Here is what to do in this situation.

  • Try to always use two layers of insulation with staggered joints. This helps prevent migration of warm, moist air up to the underside of the roof membrane. Warm air and moisture generally move upward, so drying out the roof system during warmer/sunnier days is a slow and difficult process. The goal should be to minimize or prevent condensation in the first place.
  • If a single layer of insulation is used, install cover boards, especially a high-density polyiso board, and use staggered joints.
  • If the membrane is to be fully adhered with a water-based adhesive, special care is needed to select the right one. Some have been shown to re-liquify in the presence of moisture. Our GAF water-based adhesive was formulated to limit this effect.

2. Buildings with Large Amounts of Occupancy-Generated Moisture

This category includes paper mills, laundries, buildings with indoor swimming pools, and the like. The building's air handling and ventilation systems should be carefully specified to take into account the moisture loading. Also, the entire building envelope needs to be designed and constructed in such a way that damaging condensation and moisture build-up doesn't occur. It is critical that a building science professional experienced in these types of building occupancy and designs be involved.

  • Some approaches used by building design professionals for these buildings involve the use of air and vapor barriers. Care is needed to make sure these are applied properly and without any damage to their integrity. Pay particular attention to how they are terminated around the perimeters and at penetrations.
  • Remember that roof membranes are essentially impermeable. An air and vapor barrier placed lower in the roof system can prevent any water that has managed to leak in from going elsewhere.

3. Construction–Related Moisture

Most construction practices release some amount of moisture into the building space. These can be as straightforward as drywall installation and painting although these are typically relatively short term. However, some practices can release large amounts of water over a considerable time frame into the building. Concrete slab floors have been a challenge to use with some flooring materials, and building design professionals have methods to cope with the moisture release.

Concrete roof decks can present a challenge for roof system designers especially in new construction. Regardless of the type of concrete, significant amounts of water remain after curing is completed.

  • There is very little correlation between cure time and the amount of water remaining. Guidelines such as not closing up the system until a minimum of 30 days after pouring and forming are not particularly effective at reducing or eliminating issues.
  • Concrete in new construction that appears to be dry rarely is. Water takes a long time to diffuse out of a four inch-thick slab. In fact, the NRCA no longer considers the "plastic sheet test" to be a viable indicator of concrete's surface dryness. That test involved taping a plastic sheet to the surface and monitoring moisture under it.
  • Many roof system designers require concrete decks be covered with a vapor barrier. As with buildings that have occupancy-generated moisture, care must be taken to ensure that these are specified and installed correctly. Roof membranes are essentially impermeable and any moisture that does get into the roof system will not have a path out.
  • Adopt a "belt and suspenders" approach to the roofing system and make sure any vapor barrier is terminated around the perimeter and penetrations properly. To do this, use two layers of insulation with staggered joints. When installing a fully adhered membrane with a water-based adhesive, make sure the adhesive will not re-liquify in the presence of moisture.
  • Make sure professionals who have experience with this type of construction are involved. These could include structural engineers, building science experts, and concrete suppliers.

The vast majority of roof systems give trouble-free performance for many years. When problems do occur within a few years of installation, it could be due to installation defects or moisture build-up. Roofing manufacturers try to provide a wide range of material choices so that the design professional can configure the optimum system for each building. The guidance offered here might help you to ask the right questions. However, to lower the risk of issues, make sure design professionals experienced with moisture and humidity in your region are involved.

Don't miss another GAF RoofViews post!
LATEST UPDATES
In 2022, GAF launched a first-of-its-kind initiative in Pacoima, one of the hottest neighborhoods in Los Angeles, to explore community-wide solutions to combat urban heat. The GAF Cool Community Project is addressing the complex issue of extreme heat through a research-driven approach: Take a hot, sun-exposed community with an abundance of heat-retaining surfaces. Then, apply solar-reflective coatings to its streets and public hardscapes. With resources and support from GAF and non-profit partners, more than 700,000 square feet worth of streets, parking lots, and other hardscapes were coated with StreetBond DuraShield with Invisible ShadeTM technology over a contiguous 10-block area. The formerly dark streets were transformed to a cool gray-blue, and colorful coatings brighten the basketball courts and other public gathering spaces.
Longtime fixtures of playgrounds and recreational areas, sports courts have a lot to offer. In addition to providing opportunities for children and adults to participate in physical activities, they can strengthen communities. There are also other benefits when courts are designed to reduce surface temperatures and protect substrate materials.
What is going on here? No, this roof does not have measles, it has a problem with thermal bridging through the roof fasteners holding its components in place, and this problem is not one to be ignored.
GAF is committed to building more resilient communities in the areas where we live and work. Working with our network of manufacturing communities, we can leverage our expertise, resources, and products to help protect the places we call home. Our local teams lend their time and talents to address the unique needs of each community, as we help support the fundamental needs of shelter, families and workforces.
Cold storage facilities face unique challenges when it comes to maintaining optimal interior temperature levels. Development of cold storage roofing system design documents that both maintain interior temperatures and create an airtight roof system are important to have a high-performing cold storage roof. Uncontrolled airflow into the roofing assembly can lead to condensation within the roof and the presence of icicles or ice balls at the underside of the roof deck. Condensation and ice in the roofing assembly adds weight to the roof assembly, and wet insulation has significantly reduced R-value. A reduction in R-value means that it is more difficult for the insulation to retain interior temperatures, and cooling equipment has to work harder to maintain the interior temperature set points.
Cold storage facilities face unique challenges when it comes to maintaining optimal interior temperatures. One crucial aspect in ensuring efficient temperature control is creating an airtight roof system which can help prevent cooled interior air from escaping, warmer exterior air from entering, reduce thermal loss and condensation potential, all while promoting energy efficiency and prolonging the life of the roof system and building.
This blog contains information created by a variety of sources, including internal and third party writers. The opinions and views expressed do not necessarily represent those of GAF. The content is for informational purposes only. It is not intended to constitute financial, accounting, tax or legal advice. GAF does not guarantee the accuracy, reliability, and completeness of the information. In no event shall GAF be held responsible or liable for errors or omissions in the content or for the results, damages or losses caused by or in connection with the use of or reliance on the content.

Interested in sharing or republishing our content? We kindly ask you to adhere to our guidelines.