Ventilation Calculator Based on VA/FHA Guidelines
This Calculator will help you to determine the proper amount of ventilation based
on the VA/FHA Guidelines. To use simply enter the dimension or square footage of
your attic and click 'Update'. The calculations are done for you. The products listed
are GAF/MasterFlow® products and the quantity numbers are rounded
up or down for your convenience.
Please note that the 1/300 or the 1/150 rule are general rules and do not apply
to all situations. Local Building Codes, when stricter, take precedence. Always
consult a design professional for cathedral ceilings, insulated decks, etc.
Using the FHA 1/300 rule
384.00 net free vent needed at
ridge
384.00 net free vent needed at
soffit
|
Rigid Cobra® Vents
|
Static Vents/Louvers
|
Metal Soffit Vents
|
|
|
ft. Cobra® RidgeRunner™
|
|
RT 65 Static Vents
|
|
EAC 16x4 Soffit Vents
|
|
|
ft. Cobra® Rigid Vent 2™
|
|
IR 61 Static Vents
|
|
EAC 16x8 Soffit Vents
|
|
|
ft. Cobra® Rigid Vent 3™
|
|
R 50A Static Vents
|
|
|
|
ft. Cobra® Snow Country™
|
|
IR 65 Static Vents
|
Plastic Soffit Vents
|
|
|
ft. Cobra® Snow Country Advanced™
|
|
SSB 960 Static Vents
|
|
EAP 412 Series Soffit Vents
|
|
|
Mesh Cobra® Vents
|
Turbines/Whirley Birds
|
Continuous Metal Soffit Vents
|
|
|
ft. Cobra® Exhaust Vent Hand Nail
|
|
12" Turbines
|
|
LSV8 Series Soffit Vents
|
|
|
ft. Cobra® Exhaust Vent Nail Gun
|
|
14" Turbines
|
|
LSV8L Series Soffit Vents
|
|
|
TruSlate® Ridge Vent
|
MasterFlow® Aluminum Ridge Vent
|
Plastic Circular Louvers
|
|
|
ft. TruSlate® Ridge Vent
(Prior to Q2 2010)
|
|
ft. Aluminum Ridge Vent
|
|
RLSC 2 (2") Series Soffit Vents
|
|
|
ft. TruSlate® Ridge Vent
(Q2 2010 or later)
|
|
|
RLSC 3 (3") Series Soffit Vents
|
|
|
|
RLSC 4 (4") Series Soffit Vents
|
|
MasterFlow® Power Roof Ventilators
|
MasterFlow® Power SOLAR Ventilators
|
|
|
|
PR1D 1000CFM
|
|
PRSolar 500CFM
|
Cobra® Fascia Vents
|
|
|
PR2D 1250CFM
|
|
PGSolar 500CFM
|
|
ft. Cobra® Fascia Vent 1"
|
|
|
PR3D 16000CFM
|
|
Solar Intake Booster™
|
|
ft. Cobra® Fascia Vent 1.5"
|
|
|
|
ft. Cobra® FasciaFlow™
|
|
Note: Gable vents are normally installed in pairs
|
|
|
Metal Gable Louvers
|
Plastic Gable Louvers
|
MasterFlow® Power Gable Ventilators
|
|
|
DA 12x12
|
|
SL 8x8
|
|
PG2 1540CFM
|
|
|
DA 12x18
|
|
SL 12x12
|
|
PG3 1600CFM
|
|
|
DA 14x24
|
|
SL 12x18
|
|
|
|
DA 18x24
|
|
SL 14x24
|
|
|
|
DA 24x30
|
|
SL 18x24
|
|
Using the FHA 1/150 rule
(vents placed at or near the ridge only)
1536.00 net free vent area needed
|
Rigid Cobra® Vents
|
Static Vents/Louvers
|
TruSlate® Ridge Vents
|
|
|
ft. Cobra® RidgeRunner™
|
|
RT 65 Static Vents
|
|
TruSlate® Ridge Vent
(Prior to Q2 2010)
|
|
|
ft. Cobra® Rigid Vent 2™
|
|
IR 61 Static Vents
|
|
TruSlate® Ridge Vent
(Q2 2010 and Later)
|
|
|
ft. Cobra® Rigid Vent 3™
|
|
R 50A Static Vents
|
|
|
|
ft. Cobra® Snow Country™
|
|
IR 65 Static Vents
|
MasterFlow® Aluminum Ridge Vent
|
|
|
ft. Cobra® Snow Country Advanced™
|
|
SSB 960 Static Vents
|
|
ft. Aluminum Ridge Vent
|
|
|
Mesh Cobra® Vents
|
|
|
|
ft. Cobra® Exhaust Vent Hand Nail
|
|
|
ft. Cobra® Exhaust Vent Nail Gun
|