Roof Insulation - EnergyGuard Perlite Tapered Edge Strip

EnergyGuard™

Perlite Tapered Edge Strip


Description
  • Factory fabricated from EnergyGuard™ rigid perlite insulation board.

  • Cut on angles that slope from zero on one edge to 1/2" to 2" on the opposite edge.

  • Designed for smooth transition from lower to higher elevations.

  • Easy to fabricate for installation with most types of roof systems.

  • Available in bundles 48" (1220 mm) in length.

  • Available in different heights and widths for all types of job requirements.


Uses
  • To provide smooth transition from lower to higher elevations around roof edges, drains or wherever slope to 0" is required.

  • Properly installed, EnergyGuard™ Perlite roof insulation is suitable for use under built-up, modified bitumen and some single ply roofing systems.

  • Refer to the application specifications in the current Membrane Manufacturer’s Application and Specifications manual for proper installation procedures for EnergyGuard™ Perlite roof insulation.


Specification Benefits
  • UL, ULC Flame Spread Rating 25.

  • Strong and dimensionally stable.

  • Available in standard heights and widths.

  • Can be shipped in mixed loads with roof insulation and tapered systems.

  • Multiple shipping locations.

  • Easily identifiable bundles.

  • Edge strips have at least 25% post-consumer recycled content and comply with the Environmental Protection Agency Regulation 40 CFR Part 248, “Guideline for Federal Procurement of Building Insulation Products Containing Recovered Materials,” as a recycled product approved for use on any project using federal funds.


Limitations
  • EnergyGuard™ Perlite roof insulation is a non-structural, non-load bearing material.

  • EnergyGuard™ Perlite roof insulation should be stored dry and be protected from the elements. Once properly loaded at the job site, remove factory wraps and cover with a breathable tarp.

  • No more insulation should be applied than can be completely covered with finished roofing on the same day.

  • It is NOT designed for use under fully adhered single ply systems nor for direct torch application of modified bitumen.

  • If torch grade modified bitumen roofing is to be installed over EnergyGuard™ Perlite, a fiberglass base sheet MUST first be installed.


Edge Strip Sizes*
1/2" (13 mm)
X
6" (152 mm)
X
48" (1220 mm)
1/2" (13 mm)
X
12" (305 mm)
X
48" (1220 mm)
1" (25 mm)
X
6" (152 mm)
X
48" (1220 mm)
1" (25 mm)
X
12" (305 mm)
X
48" (1220 mm)
1" (25 mm)
X
18" (457 mm)
X
48" (1220 mm)
1" (25 mm)
X
24" (610 mm)
X
48" (1220 mm)
1 1/2" (38 mm)
X
6" (152 mm)
X
48" (1220 mm)
1 1/2" (38 mm)
X
12" (305 mm)
X
48" (1220 mm)
1 1/2" (38 mm)
X
18" (457 mm)
X
48" (1220 mm)
1 1/2" (38 mm)
X
24" (610 mm)
X
48" (1220 mm)
2" (51 mm)
X
12" (305 mm)
X
48" (1220 mm)
2" (51 mm)
X
18" (457 mm)
X
48" (1220 mm)
2" (51 mm)
X
24" (610 mm)
X
48" (1220 mm)
* All sizes shown are nominal and subject to nominal manufacturing tolerances.

Documents


Residential Roofing
Shingles & Accessories
Plan Your Residential 
Roofing Project
GAF Commercial Roofing
Products & Accessories
Other GAF
Building Products
All About GAF
GAF News & Press Releases
Download Photos & Media

GAF Blogs & Social Network


© Copyright 2012 GAF | Privacy Policy and Terms of Service (Revised 6/11/2010)