Roof Insulation - EnergyGuard Perlite Recover Board

EnergyGuard™

Perlite Recover Board


Description


EnergyGuard™ Perlite Recover Board is a heavy duty, 1/2” thick perlite roof insulation board composed of expanded perlite, cellulose binders, and waterproofing agents. It is treated for surface retention of bitumen and available in 2’ x 4’ (0.6m x 1.2m) 4’ x 4’ (1.2m x 1.2m) and 4’ x 8’ (1.2m x 2.4m), with a nominal thickness of 1/2” (13mm).


Uses
  • In reroofing as a base for a variety of membranes installed over existing roof systems.

  • As a top layer in two-layer systems.

  • As an overlay board where an existing roof insulation is still functioning and could retained.

  • Where a tear-off would create unwarranted risks to operations or materials in the building.

  • To separate a new membrane from a rough or irregular substrate.

  • Properly installed, EnergyGuard™ Perlite Recover Board roof insulation is suitable for use under built-up, modified bitumen and some single ply roofing systems.


Benefits
  • Economical base for reroofing.

  • Lower installed cost than tear-offs.

  • Dimensionally stable.

  • Environmentally friendly. The minimum recycled content is 25% by weight.



Code Compliance


Recover Board is in compliance with:
  • ASTM Standard C728.

  • UL, ULC Class A construction on combustible or non-combustible roof decks. Where UL, ULC labels are required, customer must order them in advance.

  • FM for fire and wind resistance. Contact the Contractor Services Department at 1-800-766-3411 for the latest approvals.

  • Complies with the Environmental Protection Agency Regulation 40 CFR Part 248, “Guideline for Federal Procurement of Building Insulation Products Containing Recovered Materials,” as a recycled product approved for use on any project using federal funds.



Application

Recover Board can be secured by mechanical fastening or hot asphalt. If the deck is non-nailable, strip mopping is recommended to allow for moisture pressure release. Do NOT solid mop with asphalt for recover or retrofit applications. Refer to the current membrane manufacturer’s application and specifications manual for proper installation procedures.


Limitations
  • Old roofing systems must be thoroughly dry and secured before Recover Board is applied as a part of a new roof system.

  • Do NOT use Recover Board in applications where it will be directly exposed to continuous soaking temperatures in excess of 250°F.

  • EnergyGuard™ Perlite Recover Board should be stored dry and be protected from the elements. Once properly loaded at the job site, remove factory wraps and cover with a breathable tarp.

  • No more insulation should be applied than can be completely covered with finished roofing on the same day.

  • Do NOT use under fully adhered single ply systems or with direct torch application of modified bitumen.

  • If torch grade, modified bitumen roofing is to be installed over EnergyGuard™ Perlite, a fiberglass base sheet MUST first be installed.

  • Do NOT mechanically attach 1/2” recover board directly to steel decks.

NOTE: REPAIR ROOF LEAKS PROMPTLY TO AVOID ADVERSE EFFECTS, INCLUDING MOLD.

Documents


GAF Residential Roofing
Shingles & Accessories
Plan Your Residential 
Roofing Project
GAF Commercial Roofing
Products & Accessories
Other GAF
Building Products
All About GAF
GAF News & Press Releases
Download Photos & Media

GAF Blogs & Social Network

© Copyright 2012 GAF | Privacy Policy and Terms of Service (Revised 6/11/2010)