Protect Your Roof From Premature Deterioration By Providing Effective Attic Exhaust Ventilation

<< Back to Attic Ventilation

Effective attic ventilation is critical
for a long-lasting roof! A properly balanced attic ventilation system will help to:

  • Remove excess heat and moisture to protect your roof from premature deterioration
     
  • Prevent roof rot in your attic or roof deck
     
  • Minimize peeling and extend the life of exterior and interior paint
     
  • Limit the growth of harmful mold
     
  • Safeguard your attic possessions against mildew damage
     
  • Guard against ice damming in harsh winter climates
     
  • Possibly reduce excessive heating and air conditioning costs

Cobra® exhaust vent is a key part of the GAF-Elk Smart Choice® Roof System Solution, and has even earned the prestigious Good Housekeeping Seal

Homeowner’s Best Choice

  • Vents Your Attic…
    Allows heat and condensation to escape at the most effective location—the ridge.
     
  • Looks Terrific…
    100% shingle-over design is virtually invisible when installed.
     
  • Superior Protection…
    Helps to prevent wood rot and extends the life of your exterior paint.
     
  • Safeguards Possessions…
    Helps limit mildew growth caused by damp attic air.
     
  • Energy Efficient…
    May even reduce your utility bills!
     
  • Weatherproof…
    Passes 110 mph wind-driven rain and snow infiltration tests.*
     
  • Safer…
    Helps prevent problems with insects, birds, and animals in your attic.
     
  • Peace Of Mind…
    Backed by a 40-year ltd. warranty.**

*Under controlled laboratory conditions.

**See ltd. warranty for complete coverage and restrictions.

Professional’s Best Choice

  • Greater Homeowner Satisfaction…
    Low-profile design is hidden by ridge cap shingles.
     
  • Easy To Install…
    Quick, 3-step process; no need for complicated fitting, wrapping, connectors, or end plugs.
     
  • Nails Included…
    Smart Nails™ for hand-nailing, or 1 3/4" coil nails for nail guns, ensure consistent installation.
     
  • Superior Performance…
    Net free ventilating area:
     
    • Cobra® Hand Nail: 16.9 sq. in./linear foot
       
    • Cobra® Nail Gun: 14.1 sq. in./linear foot
       
  • More Reliable…
    Will not crack or dent during shipping or installation; won’t corrode, rust, or turn brittle.
     
  • Cap Shingle Compatible…
    Works with traditional size ridge cap shingles.
     
  • Two Sizes…
    Available in 20' & 50' rolls.

Balanced Ventilation Requirements

Balanced ventilation requires an equal amount of intake ventilation and exhaust ventilation. GAF-Elk recommends, at a minimum, providing 1 square foot of Net Free Ventilation for every 300 square feet of attic floor space. Consult local building codes for specific ventilation requirements in your area.

  1. Calculate the total square footage of the attic floor area (round up to the next highest number). This number will determine the minimum total linear feet of Cobra® exhaust vent that is needed.
     
  2. Find the appropriate amount of Cobra® exhaust vent and minimum intake ventilation that corresponds to the total attic square footage.
Based on 1/300 Rule
Total
Attic Square
Footage
Recommended Length of Cobra® Exhaust
Vent (Feet)*
Minimum Intake Ventilation (Net Free Area in Sq. In.)*
1600
23/28
389/395
1900
27/33
457/466
2200
32/38
541/536
2500
36/43
609/607
2800
40/48
676/677
3100
45/53
761/748
3400
49/58
829/818

*First figure pertains to hand nail, second figure pertains to nail gun.

NOTE: Always have a balanced ventilation system. In no case should the amount of exhaust ventilation at the ridge exceed the amount of soffit ventilation.

<< Back to Attic Ventilation

 



 


Class A Rated


Approval # NOA 03-1110.02
Florida Building Code FL197-R2
Cobra® Hand Nail:
YES
YES
YES
Cobra® Nail Gun:
YES
YES
YES